Anritsu Modular 1 port Vector Network Analyzer MS46131A
°æ·®, ¼ÒÇü, 1Æ÷Æ® VNA. µ¿ÀÏÇÑ PC¿¡¼ ÃÖ´ë 2°³ÀÇ VNA¸¦ Á¦¾îÇÏ¿© Return Loss Å×½ºÆ® 󸮷®(throughput) Çâ»ó. 8/20/43.5GHz ¸ðµ¨·Î 5G µð¹ÙÀ̽º¸¦ ÃøÁ¤ÇÕ´Ï´Ù.
¼³¸í :
ShockLineTM MS46131A ½Ã¸®Áî´Â 1 MHz ~ 8/20/43.5 GHz ¹üÀ§ÀÇ 3°³ÀÇ ¸ðµâ½Ä 1 Æ÷Æ® º¤ÅÍ ³×Æ®¿öÅ© ºÐ¼®±â(VNA)·Î ±¸¼ºµË´Ï´Ù. AnritsuÀÇ Æ¯Çã¹ÞÀº NLTL(Non-Linear Transmission Line) ±â¼ú VNA-on-Chip ±â¼úÀº ³»ºÎ VNA ¾ÆÅ°ÅØó¸¦ ´Ü¼øÈÇÏ¿© °èÃø±âÀÇ Å©±â¿Í ºñ¿ëÀ» Àý°¨ÇÏ´Â µ¿½Ã¿¡ Á¤È®¼º°ú ÃøÁ¤ ¹Ýº¹¼ºÀ» Çâ»ó½Ãŵ´Ï´Ù. ShockLine MS46131A ½Ã¸®Áî´Â VNA Æ÷Æ®¸¦ Å×½ºÆ® ´ë»ó ÀåÄ¡(DUT)·Î °¡Á®¿Ã ¼ö ÀÖÀ» Á¤µµ·Î ÀÛ°í È޴뼺ÀÌ ÁÁÀ¸¸ç, Å×½ºÆ® Æ÷Æ® ÄÉÀ̺íÀ» Á¦°ÅÇÏ¿© ÃøÁ¤ ¾ÈÁ¤¼ºÀ» ³ôÀÌ°í Å×½ºÆ® ±¸¼ºÀ» ´Ü¼øÈÇÕ´Ï´Ù.
ShockLine MS46131A ½Ã¸®Áî´Â ¿£Áö´Ï¾î¸µ, Á¦Á¶ ¹× ±³À° ºÐ¾ßÀÇ 1 Æ÷Æ® RF ¹× ¸¶ÀÌÅ©·ÎÆÄ ¾ÖÇø®ÄÉÀ̼ǿ¡ ÀÌ»óÀûÀÔ´Ï´Ù. ¼¼ °¡Áö VNA ¸ðµ¨Àº ¸ðµÎ ºü¸¥ ½ºÀ§ÇÁ ¼Óµµ¿Í ¿ì¼öÇÑ º¸Á¤ ÁöÇ⼺À» °¡Áö°í ÀÖ¾î ¼öµ¿ 5G mmWave ºÎÇ° ÃøÁ¤À» Æ÷ÇÔÇÑ ´Ù¾çÇÑ 1 Æ÷Æ® µð¹ÙÀ̽º Å×½ºÆ® ¾ÖÇø®ÄÉÀ̼ǿ¡ ÀûÇÕÇÕ´Ï´Ù.
µÎ °³ÀÇ µ¶¸³Çü ShockLine MS46131A VNA´Â USB¸¦ ÅëÇØ ¿ÜºÎ »ç¿ëÀÚ°¡ Á¦°øÇÏ´Â PC¿¡¼ Á¦¾î ÇÒ ¼ö ÀÖ½À´Ï´Ù. ÀÌ ½Ã¸®Áî¿¡´Â ¿Â-º¸µå(žÀçµÈ?) ¸Þ¸ð¸®°¡ ¾øÀ¸¹Ç·Î º¸¾È ¾ÖÇø®ÄÉÀ̼ǿ¡¼ »ç¿ëÀÌ °£ÆíÇÕ´Ï´Ù.
È޴뼺°ú ¼º´ÉÀÇ Á¶ÇÕÀ¸·Î ShockLine MS46131A VNA ½Ã¸®Áî´Â ¸ðµâ½Ä ¼öµ¿(Æнúê) µð¹ÙÀ̽º Å×½ºÆ® ¾ÖÇø®ÄÉÀ̼ǿ¡ ÀÌ»óÀûÀÔ´Ï´Ù.
?
»ç¾ç:
- 1 MHz ~ 8 GHz / 20 GHz / 43.5 GHzÀÇ ÁÖÆļö ¿É¼ÇÀÌ ÀÖ´Â 1 Æ÷Æ® VNA
- Extended-KTM Æ÷Æ®¸¦ ÅëÇØ 43.5 GHzÀÇ ¼º´É º¸Àå
- PC Á¦¾î·Î ¿ÜºÎ ÄÄÇ»ÅÍ Ã³¸® ´É·Â ¹× °¡´É
- ÀÛ°í °¡º¿î ÆÐÅ°Áö·Î DUT¿¡ Á÷Á¢ ¿¬°á°¡´É
- ³»Àå µ¥ÀÌÅÍ ½ºÅ丮Áö°¡ ¾øÀ¸¹Ç·Î ¾ÈÀüÇÑ ¾ÖÇø®ÄÉÀ̼ǿ¡¼ µ¥ÀÌÅ͸¦ »èÁ¦ÇÒ ÇÊ¿ä ¾øÀ½
- ¸ðµç ShockLine VNA´Â GUI ¹× ÇÁ·Î±×·¥ ȣȯ¼ºÀ» Áö¿øÇÏ´Â °øÅë ¼ÒÇÁÆ®¿þ¾î¸¦ °øÀ¯
- ŸÀÓ °ÔÀÌÆ® ¿É¼ÇÀÌ Æ÷ÇÔµÈ Å¸ÀÓ µµ¸ÞÀÎÀ¸·Î ½±°í ºü¸¥ °áÇÔ ½Äº° °¡´É
?
Application :
RF ÆÐ½Ãºê ºÎÇ° Å×½ºÆ® ¹× ¹®Á¦ ÇØ°á
1Æ÷Æ® Å×½ºÆ®¿¡¼ 43.5GHz±îÁö
´ÜÀÏ PC¿¡¼ ÃÖ´ë 2°³ÀÇ 1Æ÷Æ® VNA Á¦¾î
?
ÄÉÀ̺í Å×½ºÆ®
°áÇÔ±îÁöÀÇ °Å¸® (Distance to fault)
Return Loss
À§»ó(Phase) ÃøÁ¤
?
¾ÈÅ׳ª Å×½ºÆ®
VSWR / Return Loss
´ë¿ªÆø (Bandwidth)
?
º¸¾È ¿µ¿ª ¾ÖÇø®ÄÉÀ̼Ç
Àåºñ¿¡ µ¥ÀÌÅÍ ½ºÅ丮Áö ¾øÀ½
Á÷Á¢ USB ¿¬°áÀ» ÅëÇÑ ¿ÜºÎ ÄÄÇ»ÅÍ Á¦¾î º¸¾È
?
Frequency Options (select one frequency option only)
Option | Description | MS46131A-010 | 1 MHz — 8 GHz, type N(f) ports | MS46131A-020 | 1 MHz — 20 GHz, type ruggedized K(m) ports (compatible with 3.5 mm and SMA connectors) | MS46131A-043 | 1 MHz – 43.5 GHz, type ruggedized Extended-K™ (m) ports (compatible with standard K, 3.5 mm, and SMA connectors) |
Other Options
Option | Description | MS46131A-002 | Time Domain with Time Gating |
?
Precision Automatic Calibrator Modules
Model Number | Description | MN25208A | 2-port USB SmartCal Module, 300 kHz to 8.5 GHz (available with connector options: -001 N(f), -002 K(f), -003 3.5 mm(f), -004 SMA(f)) | MN25408A | 4-port USB SmartCal Module, 300 kHz to 8.5 GHz (available with N(f) connectors) | MN25218A | 2-port USB SmartCal Module, 1 MHz to 20 GHz (available with K(f) connectors) | MN25418A | 4-port USB SmartCal Module, 300 kHz to 20 GHz (available with K(f) connectors) | 36585K-2M | K Precision AutoCal Module, 70 kHz to 40 GHz, K(m) to K(m) | 36585K-2F | K Precision AutoCal Module, 70 kHz to 40 GHz, K(f) to K(f) | 36585K-2MF | K Precision AutoCal Module, 70 kHz to 40 GHz, K(m) to K(f) | 2000-1809-R | Serial to USB Adapter (required for 36585 AutoCal module if control PC does not have a serial port) |
Mechanical Calibration Kits
Model Number | Description | 3650A | SMA/3.5 mm Calibration Kit, Without Sliding Loads,
DC to 26.5 GHz, 50 Ω | 3650A-1 | SMA/3.5 mm Calibration Kit, With Sliding Loads,
DC to 26.5 GHz, 50 Ω | 3652A | K Connector Calibration Kit, Without Sliding Loads,
DC to 40 GHz, 50 Ω | 3653A | N Connector Calibration Kit, Without Sliding Loads,
DC to 18 GHz, 50 Ω | OSLN50A-8 | Precision N Male Open/Short/Load
Mechanical Calibration Tee, DC to 8 GHz, 50 Ω | OSLNF50A-8 | Precision N Female Open/Short/Load
Mechanical Calibration Tee, DC to 8 GHz, 50 Ω | TOSLN50A-8 | Precision N Male Through/Open/Short/Load
Mechanical Calibration Tee, DC to 8 GHz, 50 Ω | TOSLNF50A-8 | Precision N Female Through/Open/Short/Load
Mechanical Calibration Tee, DC to 8 GHz, 50 Ω | OSLN50A-18 | Precision N Male Open/Short/Load
Mechanical Calibration Tee, DC to 18 GHz, 50 Ω | OSLNF50A-18 | Precision N Female Open/Short/Load
Mechanical Calibration Tee, DC to 18 GHz, 50 Ω | TOSLN50A-18 | Precision N Male Through/Open/Short/Load
Mechanical Calibration Tee, DC to 18 GHz, 50 Ω | TOSLNF50A-18 | Precision N Female Through/Open/Short/Load
Mechanical Calibration Tee, DC to 18 GHz, 50 Ω | TOSLK50A-20 | Precision K Male Through/Open/Short/Load
Mechanical Calibration Tee, DC to 20 GHz, 50 Ω | TOSLKF50A-20 | Precision K Female Through/Open/Short/Load
Mechanical Calibration Tee, DC to 20 GHz, 50 Ω | TOSLK50A-40 | Precision K Male Through/Open/Short/Load
Mechanical Calibration Tee, DC to 40 GHz, 50 Ω | TOSLKF50A-40 | Precision K Female Through/Open/Short/Load
Mechanical Calibration Tee, DC to 40 GHz, 50 Ω | TOSLK50A-43.5 | Precision K Male Through/Open/Short/Load
Mechanical Calibration Tee with S1P data, DC to 43.5 GHz, 50 Ω | TOSLKF50A-43.5 | Precision K Female Through/Open/Short/Load
Mechanical Calibration Tee with S1P data, DC to 43.5 GHz, 50 Ω |
?
Anritsu has partnered with the following industry-leading companies to provide a variety of proven material measurement capabilities that are compatible with the VectorStar and ShockLine vector network analyzer families.
?
Third party Material Measurements
| Compass Technology
Choose from off-the-shelf or custom-designed RF material measurement systems able to measure material properties from 100 MHz to 90 GHz. These solutions include: focused beam, resonant cavity, waveguides, spot probes, free space measurement systems, and more.
?
Anritsu and Compass Technology Group Material Measurements Solutions
Compass Technology Group VectorStar Integration [video] | | Keycom Technologies
Select from a variety of material measurement solutions that leverage various methods including: resonator, frequency change, probe type, co-axial tube and waveguide type S-parameter, free space, capacitance, epsilometery, and more.
?
Anritsu and Keycom Material Measurement Solution | | SWISSto12
Providing hardware and software technology capable of measuring: solid samples; soft sample and foam; liquid samples and powder; thin films; dielectric coatings and multilayer materials; alumina plate; and more.
?
Anritsu and SWISSto12 Material Measurement Solution |
|