XANTREX / Power Supply / XFR-60-46
Product Specifications
Output Voltage 0-60 V
Output Current0-46 A
Output Power 2760 W
Line Regulation2 Voltage 8 mV
Current 6.6 mA
Common
Switching Frequency XFR 2.8 kW: Nominal 31 kHz (62 kHz output ripple) XFR 1.2 k
W: 6 V to 40 V models: nominal 78 kHz (156 kHz output ripple); 60 V to
600 V models: nominal 62.5 kHz (125 kHz output ripple).
Time Delay 7 sec maximum from power on until output stable
Voltage Mode Transient Response Time < 3 ms for output voltage to recover within
0.5% of its rated voltage after a step change in load current of up
to 10% to 90% of rated output
Maximum Voltage Differential ±600 Vdc from output to safety ground
Remote Start/Stop and Interlock 2.5-15 V signal or TTL-compatible input, selecta
ble logic
Remote Analog Programming Voltage and current programming inputs (source must be
isolated): 0-5 k, 0-10 k resistances; 0-5 V, 0-10 V (default) voltage sources
Remote Analog Monitoring Voltage and current monitor outputs 0-5 V, 0-10 V (defa
ult) ranges for 0-100% of output
Remote Programming &
Monitoring Accuracy
1% zero to full scale output for the default range
Maximum Remote Sense
Line Drop Compensation
5 V / line (Line drop is subtracted from total voltage available at supply outpu
t.)
Front Panel Voltage and Current Control 10-turn voltage and current potentiomete
rs
Front Panel Voltage Control Resolution 0.02% of maximum voltage
Main Output Connector XFR 2.8 kW: 7.5 - 100 V models: nickel-plated copper bus b
ars with bus bar cover and strain relief; 150V to 600 V models: 4-terminal,
wire clamp connector with cover and strain relief; XFR 1.2 kW: 6 - 40 V models:
nickel-plated copper bus bars with bus bar shield;
60 - 600 V models: 4-terminal wire clamp connector with strain relief
Approvals CE-marked units meet: EN61010-1, EN61000-6-2 and EN61000-6-4; UL Liste
d to UL3111-1; CSA certified to CSA C22.2 No 1010.1
Meets USA EMC standard: FCC, part 15B, Class A; Meets Canadian EMC standard: ICE
S-001, Class A.
Environmental
Operating Temperature XFR 2.8 kW: 0 to 50°C, XFR 1.2 kW: 0 to 50°C; 6 V model:
for rack mounted units, derate output current by 1.5 A per °C
for operating temperatures between 30 - 50°C
Storage Temperature -20°C to 70°C
Humidity (Non-condensing) Up to 90% RH, non-condensing
Physical XFR 2.8 kW XFR 1.2 kW
Dimensions Width: 19” (429.4 mm)
Height: 3.5” (88.9 mm)
Depth: 21” (533.5 mm)
Width: 19” (429.4 mm)
Height: 1.7” (43.2 mm)
Depth: 20” (508.1 mm)
Weight 33 lb (15 kg)
OPTION