제품 상세보기

  • Tektronix/Waveform monitor/1730
  • Tektronix/Waveform monitor/1730
  • Tektronix/Waveform monitor/1730

Tektronix / Waveform monitor / 1730
Analog Waveform Monitors
1720 Series • 1730 Series 
Features & BenefitsPerformance and EconomyFull Frame Line SelectSimultaneous Channel A and B DisplayDual Filter DisplayOne-button Front Panel RecallRGB/YRGB Display Capability1730 Series Displays D-2 Servo WaveformsParallax-free Internal GraticulesDifferential Phase and Gain MeasurementStereo Audio Phase MeasurementVector Center Dot ClampingRemote Control CapabilityAvailable in NTSC and PAL Standards as Well as Dual StandardWhite Phosphor AvailableComposite Serial and Parallel Monitoring Is Available with 1730D SeriesApplicationsCost-effective Signal Monitoring in Camera Control Consoles and Video Transmission ApplicationsThe Tektronix 1730 Series Waveform Monitors and 1720 Series Vectorscopes provide comprehensive television signal monitoring for both NTSC and PAL applications. These versatile instruments are light weight, half-rack width and have bright CRTs for video signal monitoring. Both instruments exceed normal monitoring capabilities, and their unique features make them even more powerful when operated in tandem. Each monitor has its own advanced feature set and the proven 1700 Series family performance to provide more monitor for the money. These monitors do the job faster, better and easier at an economical price.
The 1720 Series and 1730 Series families cover a wide variety of video testing needs. For typical composite monitoring in the NTSC and PAL realm, the 1720 Series and 1730 Series more than handle the job. If there is a need for Dual Standard testing (PAL and NTSC), the 1735 Waveform Monitor and 1725 Vectorscope can be used. Digital testing of both composite parallel and composite serial can be accomplished with the 1730D Series of Digital Waveform Monitors. Whatever the individual video testing application, the 1720 and 1730 Series family provide an easy to use, economical solution.
Complete Line SelectThe 1730 Series Waveform Monitor has full frame line select, with alphanumeric readout, that can be tracked by the 1720 Series Vectorscope when in Auxiliary mode. Any one or two lines of the entire frame can be selected and displayed or the same line(s) in both fields can be viewed at one time. An intensified zone in the two-field sweep and on the picture monitor output signal indicates the location of the line selection. In addition, any successive 15 lines can be overlaid for camera and VTR adjustments.
Simultaneous Channel A and B displayThese instruments have microprocessor front panel control. They are operator-friendly and provide outstanding features in half-rack waveform monitors or vectorscopes. Both the 1730 Series Waveform Monitor and the 1720 Series Vectorscope have dual channel display capability, allowing both input channels to be displayed on the CRT simultaneously.
 
1730 Waveform Monitor - Simultaneous Channel A and B display. 

Dual Filter DisplayThe 1730 (NTSC) and the 1731 (PAL) Waveform Monitor include dual filter display, which provides low pass and flat information in the same display. The 2-Field and 2-Line Display Modes have the Low Pass Filter applied to the left half of the trace. In the 1-Line Mode, the two signals are overlaid. These filter modes can also be used independently. Both versions of the 1730 Series have chroma filters centered around the subcarrier frequency.
One-Button Front Panel RecallOnce the front panel has been set up in a frequently used mode, the configuration can be stored for later one-button recall. In addition, when the 1720 is used in tandem with the 1730, it will respond to this Store/Recall operation. Up to four operator-selected front panel configurations can be stored from the front panel. Four other front panel configurations are factory-programmed settings and are accessible from the Remote Control interface.
 
1730 NTSC Dual Filter display. 

 
1720 Stereo Audio display with phase error. 

 
1721 PAL Vector display. 

 
1731 PAL Dual Filter display. 

 
Line Select Test Signal display. 

 
1720 NTSC Vector display. 

Differential Phase And Gain MeasurementsThe 1720 Series Vectorscope graticule has scales for measuring Differential Phase and Gain. The Differential Phase scale has markings at 2° intervals. The Differential Gain scale has markings at 5% intervals. For even greater precision, the 1720 and 1730 Series can be coupled for differential phase measurements using the field or line sweep on the 1730 Series Waveform Monitor. The Waveform Monitor Chroma filter can be used for differential gain measurements.
Stereo Audio Phase MeasurementsBalanced inputs for the X Y mode are available on the 1720 Series Vectorscope through a separate input connector. This mode is particularly useful for evaluation of stereo audio with a special X Y graticule scale for both amplitude and phase measurements. X Y measurements can be displayed individually or in combination with a vector display. This input can also be used for other applications where X Y monitoring is useful.
RGB-YRGBThe Waveform Monitor can display RGB or YRGB. The RGB/YRGB staircase input is through a rear panel connector.
Vector Center Dot ClampingThe 1720 Series Vectorscopes employ center dot clamping in Vector mode for easy detection of residual sub-carrier on the signal. In addition, with no signal present, the center dot automatically dims prolonging the CRT life.
Parallax-Free Internal GraticulesBoth instruments utilize post-accelerated, mesh-type CRTs equipped with internal graticules to provide parallax-free displays. Variable, evenly-illuminated scales, along with molded bezels, make waveform photography a snap.
Remote ControlInternal front panel presets, RGB/YRGB enable, along with front panel recall/setup can be accessed through the waveform monitor remote connector.
Available in NTSC, PAL and Dual StandardBoth the 1730 Series and the 1720 Series are available in either NTSC or PAL versions. The 1721 Vectorscope and the 1731 Waveform Monitor are the PAL versions. The 1735 Waveform Monitor and 1725 Vectorscope provide PAL/NTSC Dual Standard Monitoring.

Characteristics
1730 Series Waveform Monitors Characteristics
 
1730 Series rear panel. 


Signal Input (Video and External Reference) 

Return Loss - >40 dB, 50 kHz to 6 MHz, power on or off.

Maximum Input - ±5 V DC + peak AC.

Loop-through Isolation - >80 dB at FSC.

Channel Isolation - >50 dB at FSC.

Impedance - >15 kΩ.

Vertical Deflection 

Deflection Factor - Within 1% of 1 V.

Gain Range - Input signals between 0.8 V and 2 V can be adjusted to a 1 V display; (160 mV and 400 mV for X5 gain).

Position Range - 1 V signal can be positioned so that peak white and sync tip can be placed at blanking level regardless of gain range.

Frequency Response 

Flat - 50 kHz to 6 MHz within 2% (X1), within 5% (X5).

Low Pass - 40 dB attenuation at FSC; Low pass response within 1% of flat response (1735: 30 dB).

Chroma - Nominal bandwidth 1 MHz; 2X FSC attenuation >20 dB; Chroma response within 1% of flat response.

Transient Response 

Preshoot - <1%.

Overshoot - <2%.

Ringing - <2%.

Tilt - <1%.

Pulse-to-Bar Ratio - 0.99:1 to 1.01:1.

Differential Gain - <1%.

DC Restoration 

Clamp Time - Back porch.

Frequency Response - Attenuation of 60 Hz on input signal:

Slow mode: <20%.

Fast mode: >90%.


Blanking Level Shift - A 10% to 90% APL change will cause <1% of blanking level shift. Presence or absence of color burst will cause <1% of blanking shift.

PIX Monitor Output 

Frequency Response - 50 kHz to 6 MHz within 3%.

Differential Gain - <1%.

Differential Phase - <1%.

DC Level on Output - <0.5 V into 75 Ω load.

Intensification (Brightup) - 180 mV DC offset on select lines.

Output Impedance - 75 Ω nominal.

Return Loss - >30 dB, 50 kHz to 6 MHz.

Input to Output (PIX MON) Gain Ratio Luminance - 1:1 ±5% at 15 kHz.

Calibrator 

Frequency - 100 kHz ±0.1 kHz.

Timing Accuracy - 10 μs, ±0.01 μs.

Amplitude - 1 V, ±1%.

Horizontal Deflection System 

Sweep - Sweep will occur with or without input signal.

1-Line Repetition Rate - Equal to applied line rate, magnification equals 0.2 ms/div.

2-Line Repetition Rate - Equal to half applied line rate, magnification equals 1 ms/div.

2-Field Repetition Rate - Equal to applied frame rate, magnification equals X25.

Timing Accuracy - 1 ms/div.: Within 2%.

0.2 ms/div.: Within 3%.


Linearity - Within 2%.

Differential Linearity - Within 2%.

Sweep Magnification Registration - Magnification occurs about the center of the screen.

Position Range - Any portion of a synchronized video sweep can be positioned on screen in all sweep modes.

Synchronization 

Internal - Composite video or black burst with sync ±6 dB of nominal.

External - Sync amplitude of 143 mV to 4 V.

Remote Sync - 2.0 to 5.0 V square wave or 4.0 V comp sync (sync polarity can be internally inverted).

RGB/YRGB - Repetition rate: Field rate and line rate with magnification of X25 and X10, respectively.

Sweep length:

3-Step (RGB): 3.4 to 4.1 divs.

4-Step (YRGB): 2.5 to 3.1 divs.


1720 Series Vectorscopes Characteristics
 
1720 Series rear panel. 


Signal Input (Video and External Reference) 

Return Loss - >40 dB, 50 kHz to 6 MHz, power on or off.

Maximum Input - ±5 V DC + peak AC.

Loop-through Isolation - >70 dB at FSC.

Channel Isolation - >70 dB at FSC.

Impedance - >15 kΩ.

Chrominance Bandwidth 

Upper - -3 dB point, FSC +500 kHz, ±100 kHz.

Lower - -3 dB point, FSC -500 kHz, ±100 kHz.

Vector Phase Accuracy - Within 1.25°.

Vector Gain Accuracy - Within 2.5%, typical.

Quadrature Phasing - Within 0.5°, typical.

Subcarrier Regenerator 

Pull-in Range - FSC ±50 Hz.

Pull-in Time - Within 1 second.

Phase Shift with Subcarrier Frequency Change - 2° ±50 Hz.

Phase Shift with Burst Amplitude Change - <2° with ±6 dB change from nominal.

Phase Shift with Input Channel Change - <0.5°.

Phase Change with Variable Gain Control - ±1°.

Phase Control Range - 360° Continuous rotation.

Burst Jitter - <0.5°.

Display Differential Phase and Gain - ±1° and ±1%.

Center Dot Clamp Stability - <0.4 mm spot movement.

Synchronization 

Internal - Composite video with sync ±6 dB of nominal.

External Reference - Composite video or CW subcarrier.

X Y mode 

Input - Differential, DC coupled.

Input Amplitude - 2 to 9 Vp-p, adjustable full scale deflection 0 dBm to +12 dBm for 600 Ω system, factory set to 0 dBm.

Maximum Input - ±15 V peak signal + DC.

Frequency Response - DC to 500 kHz (DC to 100 kHz high-gain mode).

X and Y Phase Match - Less than a trace width separation at 20 kHz.

1720 and 1730 Series Common Characteristics
CRT Viewing Area - 80 x 100 mm.

Trace Rotation - 8° range, typical.

Graticule - Internal scale with variable illumination.

Power Source
Mains Voltage Ranges - 115 V, 90-132 V, 230 V, 200-250 V.

Mains Frequency Range - 48 Hz to 66 Hz.

Power Consumption - 25 W (85 BTU/HR) maximum.

Environmental
Temperature - Nonoperating: -55°C to +75°C.

Operating: 0°C to +50°C.


Altitude - Nonoperating: To 15,240 m (50,000 ft.).

Operating: To 2,000 m (6,500 ft.).


Shock - Nonoperating: 30 Gs, 1/2 sine, 11 ms duration, 3 shocks per surface (18 total).

Transportation - Qualified under NSTA Test Procedure 1A, Category II (30-inch drop).


Humidity - Meets Tektronix Standard 062-2847-00.

Certifications
EMC - Certified to the EMC Directive 89/336/EEC.

Safety - Approved to: UL1244, CSA231.

Complies with: EN61010-1, IEC61010-1.


Physical characteristics 

Dimensions
 mm
 in.
 
Weight
 kg
 lbs.
 
Height
 133.4
 5.25
 
Width
 215.9
 8.5
 
Length
 460.4
 8.125
 
Approximately
 3.8
 18.125
 

Ordering Information1720Vectorscope (for NTSC System Applications).
1721Vectorscope (for PAL System Applications).
1725Vectorscope (for PAL/NTSC dual System Applications).
1730Waveform Monitor (for NTSC System Applications).
1731Waveform Monitor (for PAL System Applications).
1735Waveform Monitor (for PAL/NTSC dual System Applications).
All Include: Instruction manual, power cable assembly, spare fuse, auxiliary control cable 012-1422-01 (1720 Series only).
Opt. 74 - Substitute P4 (white) phosphor on CRT on these models: 1720, 1725, or 1735.
Optional AccessoriesItem
 Description
 
1700F00
 Plain cabinet; for half-rack 1700 Series and WFM601 Series, safety controlled
 
1700F00A
 Rackmount insert; for WFM700 Series, half-rack 1700 Series and WFM601 Series
 
1700F02
 Portable cabinet; includes handle, feet, and tilt stand
 
1700F06
 Filler panel; covers unused rack space in WFM7F05
 
1700F07
 Drawer; half-rack, fits WFM7F05 dual-rack cabinet
 
WFM7F05
 Rack adapter; dual side-by-side for WFM700, 1700 Series, and WFM601 Series
 
ServiceOpt. R5 - Repair Service 5 Years



--------------------------------------------------------------------------------
 
 
OPTION

Product Info

  • Manufacturer : Tektronix
  • Product : Waveform monitor
  • Model : 1730
  • Link : none
  • Tel Service : 02-3666-6341
  • File-1 : none
  • File-2 : none
  • File-3 : none
  • UserPrice : ₩500,000
  • RentalPrice :₩85,000